Item Name | Switch Pressure |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5930 Switches |
National Item Identification Number (NIIN) | 01-523-6686 (015236686) |
Part Number | Manufacturer | Item Name | RFQ |
---|---|---|---|
P110-55W3A-X 9417 | wasco sales and marketing inc | switch pressure | RFQ |
7451-02 | wasco sales and marketing inc | switch pressure | RFQ |
7451A-02 | wasco sales and marketing inc | switch pressure | RFQ |
7451A-02 | howell laboratories inc | switch pressure | RFQ |
7595-ITEM NO 3 | wasco sales and marketing inc | switch pressure | RFQ |
7595-ITEM NO 3 | howell laboratories inc | switch pressure | RFQ |
7451-02 | howell laboratories inc | switch pressure | RFQ |
P110-55W3A-X 9417 | howell laboratories inc | switch pressure | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 2.312 INCHES NOMINAL |
ADAV | OVERALL DIAMETER | 1.031 INCHES NOMINAL |
AJZC | PRESSURE SWITCH TYPE | DIFFERENTIAL |
AXGY | MOUNTING METHOD | INPUT PORT |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
CSCF | TERMINAL TYPE | WIRE LEAD |
CTHF | CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD SINGLE VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE, PRESET AND DEACTUATION POINT ADJUSTABLE, PRESET |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT LOCK RING |
CTYX | CONTACT STIMULUS RATING | 125.00 ACTUATION POINT NOMINAL POUNDS PER SQUARE INCH |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 250.0 AC AT SEA LEVEL SINGLE VOLTAGE |
FREQ | FREQUENCY IN HERTZ | 60.0 SINGLE VOLTAGE |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR GAS, LIQUEFIED |
STYL | III STYLE DESIGNATOR | CYLINDRICAL |
ABHP | OVERALL LENGTH | 2.312 INCHES NOMINAL |
ADAV | OVERALL DIAMETER | 1.031 INCHES NOMINAL |
AJZC | PRESSURE SWITCH TYPE | DIFFERENTIAL |
AXGY | MOUNTING METHOD | INPUT PORT |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
CSCF | TERMINAL TYPE | WIRE LEAD |
CTHF | CONTACT LOAD CURRENT RATING | 5.0 AMPERES RESISTIVE LOAD SINGLE VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE, PRESET AND DEACTUATION POINT ADJUSTABLE, PRESET |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT LOCK RING |
CTYX | CONTACT STIMULUS RATING | 125.00 ACTUATION POINT NOMINAL POUNDS PER SQUARE INCH |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 250.0 AC AT SEA LEVEL SINGLE VOLTAGE |
FREQ | FREQUENCY IN HERTZ | 60.0 SINGLE VOLTAGE |
MEDA | MEDIA FOR WHICH DESIGNED | GAS OR GAS, LIQUEFIED |
STYL | III STYLE DESIGNATOR | CYLINDRICAL |
Relevant Components for NSN - 5930-01-523-6686, 5930015236686 | ||||
5905-00-000-0136 (5905000000136) | 5905-00-001-2573 (5905000012573) | 5905-00-001-2813 (5905000012813) | 5905-00-001-2834 (5905000012834) | |
5905-00-001-2852 (5905000012852) | 5905-00-001-2882 (5905000012882) | 5905-00-001-2890 (5905000012890) | 5905-00-001-2920 (5905000012920) | |
5905-00-001-2934 (5905000012934) | 5905-00-001-2951 (5905000012951) | 5905-00-001-2952 (5905000012952) | 5905-00-001-2954 (5905000012954) | |
AS9120B and ISO 9001:2015 |
|
Aviation Suppliers Association Member |
|
FAA AC 0056B Accredited |
|
AS 6081:2012 Certification |
|
ESD S20.20-2014 Certification |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.