Item Name | Switch Thermostatic |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5930 Switches |
National Item Identification Number (NIIN) | 00-832-9895 (008329895) |
Part Number | Manufacturer | Item Name | RFQ |
---|---|---|---|
54689-1 | keco industries inc | switch thermostatic | RFQ |
10K93 | zeks air drier corp | switch thermostatic | RFQ |
2042D66 | zeks air drier corp | switch thermostatic | RFQ |
416-32 | essex group inc | switch thermostatic | RFQ |
30041-1 | sensata technologies inc | switch thermostatic | RFQ |
20425F | texas instruments incorporated | switch thermostatic | RFQ |
20425F | sensata technologies inc | switch thermostatic | RFQ |
20425F42-411-650 | texas instruments incorporated | switch thermostatic | RFQ |
2455-12 | sensata technologies inc | switch thermostatic | RFQ |
SWT58 | trane co | switch thermostatic | RFQ |
2042D66 | sensata technologies inc | switch thermostatic | RFQ |
20425F | zeks air drier corp | switch thermostatic | RFQ |
30041-1 | zeks air drier corp | switch thermostatic | RFQ |
2455-12 | honeywell international inc | switch thermostatic | RFQ |
2455-12 | zeks air drier corp | switch thermostatic | RFQ |
2042D66 | texas instruments incorporated | switch thermostatic | RFQ |
SWT58 | sensata technologies inc | switch thermostatic | RFQ |
C4524-1352 | trane co | switch thermostatic | RFQ |
SWT58 | zeks air drier corp | switch thermostatic | RFQ |
30041-1 | honeywell international inc | switch thermostatic | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | III OVERALL LENGTH | 2.000 INCHES MAXIMUM |
ABKW | OVERALL HEIGHT | 1.016 INCHES MAXIMUM |
ABPM | BODY DIAMETER | 0.984 INCHES MAXIMUM |
ABTD | MOUNTING SLOT WIDTH | 0.176 INCHES NOMINAL |
ADAU | BODY HEIGHT | 0.993 INCHES NOMINAL |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 1.563 INCHES MINIMUM AND 1.688 INCHES MAXIMUM |
AKBY | TEMP SENSING ELEMENT TYPE | INTERNAL SENSOR |
AXGY | MOUNTING METHOD | BRACKET AND SLOT |
CBBL | FEATURES PROVIDED | TAMPER PROOF CAP |
CQGB | CONTACT ACTION STIMULUS | DECREASE |
CQYJ | MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
CSCF | TERMINAL TYPE | WIRE LEAD |
CTHF | CONTACT LOAD CURRENT RATING | 100.0 MILLIAMPERES RESISTIVE LOAD SINGLE VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
CTYX | CONTACT STIMULUS RATING | 0.00 ACTUATION POINT NOMINAL DEGREES FAHRENHEIT AND 10.00 DEACTUATION POINT NOMINAL DEGREES FAHRENHEIT |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 208.0 AC AT SEA LEVEL SINGLE VOLTAGE |
MEDA | MEDIA FOR WHICH DESIGNED | GAS |
STYL | III STYLE DESIGNATOR | DISC W/FLANGE |
Relevant Components for NSN - 5930-00-832-9895, 5930008329895 | ||||
5905-00-000-0136 (5905000000136) | 5905-00-001-2573 (5905000012573) | 5905-00-001-2813 (5905000012813) | 5905-00-001-2834 (5905000012834) | |
5905-00-001-2852 (5905000012852) | 5905-00-001-2882 (5905000012882) | 5905-00-001-2890 (5905000012890) | 5905-00-001-2920 (5905000012920) | |
5905-00-001-2934 (5905000012934) | 5905-00-001-2951 (5905000012951) | 5905-00-001-2952 (5905000012952) | 5905-00-001-2954 (5905000012954) | |
AS9120B and ISO 9001:2015 |
|
Aviation Suppliers Association Member |
|
FAA AC 0056B Accredited |
|
AS 6081:2012 Certification |
|