Item Name | Switch Pressure |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5930 Switches |
National Item Identification Number (NIIN) | 00-190-8729 (001908729) |
Part Number | Manufacturer | Item Name | RFQ |
---|---|---|---|
P20DA-116C | cecom lr center | switch pressure | RFQ |
13216E6215-3 | johnson controls inc | switch pressure | RFQ |
5930001908729 | e c a etablissement central | switch pressure | RFQ |
13216E6215-3 | cecom lr center | switch pressure | RFQ |
210AP40AN445P0RM10M0DIFIED | johnson controls inc | switch pressure | RFQ |
MODP20DA-180PENH | johnson controls inc | switch pressure | RFQ |
210AP40AN445P0RM10M0DIFIED | cecom lr center | switch pressure | RFQ |
P20DA-116 | cecom lr center | switch pressure | RFQ |
P20DA-116G | cecom lr center | switch pressure | RFQ |
P20DA-116 | johnson controls inc | switch pressure | RFQ |
P20DA-116G | johnson controls inc | switch pressure | RFQ |
P20DA-116C | johnson controls inc | switch pressure | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AAJD | THREAD CLASS | 2B ALL THREADED HOLE |
ABHP | OVERALL LENGTH | 2.703 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 2.640 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 1.125 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 2.190 INCHES NOMINAL |
AEJN | DISTANCE BETWEEN MOUNTING FACILITY CENTERS | 0.688 INCHES NOMINAL |
AJZC | PRESSURE SWITCH TYPE | ABSOLUTE |
AWTN | OPERATING TEMP RATING | -65.0 DEG FAHRENHEIT MINIMUM AND 160.0 DEG FAHRENHEIT MAXIMUM |
AXGY | MOUNTING METHOD | BASE AND THREADED HOLE |
CBBL | FEATURES PROVIDED | MANUAL RESET BUTTON |
CMLP | THREAD QUANTITY PER INCH | 32 ALL THREADED HOLE |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CQJB | PROOF PRESSURE | 600.00 POUNDS PER SQUARE INCH GAGE |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES ALL THREADED HOLE |
CQYJ | MOUNTING FACILITY PATTERN | TWO POSITION IN-LINE |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION |
CSCF | TERMINAL TYPE | QUICK DISCONNECT, MALE |
CTHF | CONTACT LOAD CURRENT RATING | 8.0 AMPERES RESISTIVE LOAD SINGLE VOLTAGE |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT NOT ADJUSTABLE |
CTYX | CONTACT STIMULUS RATING | 445.00 ACTUATION POINT NOMINAL POUNDS PER SQUARE INCH GAGE |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 240.0 AC AT SEA LEVEL SINGLE VOLTAGE |
FREQ | FREQUENCY IN HERTZ | 60.0 SINGLE VOLTAGE |
MEDA | MEDIA FOR WHICH DESIGNED | GAS |
STYL | III STYLE DESIGNATOR | RECTANGULAR |
THSD | THREAD SERIES DESIGNATOR | UNC ALL THREADED HOLE |
Relevant Components for NSN - 5930-00-190-8729, 5930001908729 | ||||
5905-00-000-0136 (5905000000136) | 5905-00-001-2573 (5905000012573) | 5905-00-001-2813 (5905000012813) | 5905-00-001-2834 (5905000012834) | |
5905-00-001-2852 (5905000012852) | 5905-00-001-2882 (5905000012882) | 5905-00-001-2890 (5905000012890) | 5905-00-001-2920 (5905000012920) | |
5905-00-001-2934 (5905000012934) | 5905-00-001-2951 (5905000012951) | 5905-00-001-2952 (5905000012952) | 5905-00-001-2954 (5905000012954) | |
AS9120B and ISO 9001:2015 |
|
Aviation Suppliers Association Member |
|
FAA AC 0056B Accredited |
|
AS 6081:2012 Certification |
|
ESD S20.20-2014 Certification |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote