Item Name | Circuit Breaker |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5925 Circuit Breakers |
National Item Identification Number (NIIN) | 00-001-5914 (000015914) |
Part Number | Manufacturer | Item Name | RFQ |
---|---|---|---|
3363-20AMP | eaton corp | circuit breaker | RFQ |
11900289 | fairbanks morse llc | circuit breaker | RFQ |
3363-20-208VAC60HZCURVE2 | u s dept of transportation federal | circuit breaker | RFQ |
11900289 | coltec industries inc | circuit breaker | RFQ |
3363-20-208VAC60HZCURVE2 | eaton corp | circuit breaker | RFQ |
402023-1 | raytheon company | circuit breaker | RFQ |
3363-20-250-60-2 | eaton corp | circuit breaker | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | MULTIPOLE-SINGLE ACTUATOR TYPE |
ADAQ | BODY LENGTH | 5.250 INCHES NOMINAL |
ADAT | BODY WIDTH | 3.000 INCHES NOMINAL |
ADAU | BODY HEIGHT | 2.687 INCHES NOMINAL |
ADTV | CASE MATERIAL | PLASTIC |
AEBP | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO LENGTH | 4.359 INCHES NOMINAL |
AEBQ | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO WIDTH | 1.000 INCHES NOMINAL |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.190 INCHES NOMINAL |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 4.359 INCHES NOMINAL |
AEHA | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH | 1.000 INCHES NOMINAL |
AGAV | III END ITEM IDENTIFICATION | ASR7 |
AJEC | BOSS HEIGHT | 0.219 INCHES NOMINAL |
AKPX | POLE QUANTITY | 3 |
APNQ | III ARC QUENCHING METHOD | MAGNETIC BLOWOUT |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE |
BBRG | III STORAGE TYPE | GENERAL PURPOSE WAREHOUSE |
CPLM | MAXIMUM CONTINUOUS LOAD CURRENT RATING PER POLE | 20.0 AMPERES AC ALL LOCATIONS |
CPRF | OPERATING VOLTAGE TYPE AND RATING PER POLE IN VOLTS | 250.0 AC ALL LOCATIONS |
CPRG | MAXIMUM INTERRUPTING CAPACITY CURRENT TYPE AND RATING PER POLE IN AMPS | 5000.0 AC ALL LOCATIONS |
CPRH | CIRCUIT PROTECTION TYPE | OVERCURRENT ALL LOCATIONS |
CPRJ | TRIP RELEASE METHOD | MAGNETIC-HYDRAULIC ALL LOCATIONS |
CPRL | TRIP RELEASE CHARACTERISTIC | TIME DELAY ALL LOCATIONS |
CPRN | ULTIMATE TRIP RATING OF CONTINUOUS CURRENT RATING PER POLE IN PERCENT | 125.0 ALL LOCATIONS |
CPRQ | RESET METHOD | MANUAL |
CPRR | MAIN CONTACT TRIPPING MECHANISM TYPE | TRIP FREE |
CPRT | MANUAL ACTUATOR TYPE AND QUANTITY | 1 TOGGLE |
CPRW | ACTUATOR FUNCTION | TRIP-RESET |
CPRX | ACTUATOR POSITION DESIGNATION | AT POLE TWO |
CPSM | INTERNAL TRIP RELEASE CONFIGURATION | SERIES TRIP ALL LOCATIONS |
CQWN | TRIP DELAY TIME IN SECONDS PER RATED CONTINUOUS CURRENT | 13.000 MINIMUM AT 150 PCT ALL LOCATIONS AND 45.000 MAXIMUM AT 150 PCT ALL LOCATIONS AND 5.500 MINIMUM AT 200 PCT ALL LOCATIONS AND 19.000 MAXIMUM AT 200 PCT ALL LOCATIONS |
CQXF | INCLOSURE PROTECTION TYPE FOR WHICH DESIGNED | FUNGUS RESISTANT AND MOISTURE RESISTANT |
FREQ | FREQUENCY IN HERTZ | 60.0 ALL LOCATIONS |
PKWT | III UNPACKAGED UNIT WEIGHT | 1.875 POUNDS |
TTQY | TERMINAL TYPE AND QUANTITY | 6 COMPRESSION |
Relevant Components for NSN - 5925-00-001-5914, 5925000015914 | ||||
5905-00-000-0136 (5905000000136) | 5905-00-001-2573 (5905000012573) | 5905-00-001-2813 (5905000012813) | 5905-00-001-2834 (5905000012834) | |
5905-00-001-2852 (5905000012852) | 5905-00-001-2882 (5905000012882) | 5905-00-001-2890 (5905000012890) | 5905-00-001-2920 (5905000012920) | |
5905-00-001-2934 (5905000012934) | 5905-00-001-2951 (5905000012951) | 5905-00-001-2952 (5905000012952) | 5905-00-001-2954 (5905000012954) | |